01
Retail and small C&I
Peak shaving behind the meter where the electrical room is already full. One cabinet, one wall circuit.
Three floor-standing LiFePO4 cabinets at 51.2 V. No rack, no dedicated room, no wall to carry 228 kg. Roll it in, wire it up, commission it.
Product range
The cabinet grows in floor area, not in height, so a 30 kWh unit still fits under a standard industrial ceiling. All three share the same BMS, the same communication protocol and the same commissioning procedure.
| Parameter | 15 kWh | 20 kWh | 30 kWh |
|---|---|---|---|
| Nominal voltage | 51.2 V | 51.2 V | 51.2 V |
| Rated capacity | 300 Ah | 400 Ah | 600 Ah |
| End-of-charge voltage | 58.0 V | 58.0 V | 58.0 V |
| End-of-discharge voltage | 42.0 V | 42.0 V | 42.0 V |
| Max. charge current | 200 A | 200 A | 200 A |
| Max. discharge current | 200 A | 200 A | 200 A |
| Communication | RS485 / CAN | RS485 / CAN | RS485 / CAN |
| Dimensions (mm) | 495×240×880 | 510×293×970 | 460×380×995 |
| Weight | 115 kg | 147 kg | 228.7 kg |
| Chemistry | LiFePO4 | LiFePO4 | LiFePO4 |
Cabinet dimensions are width × depth × height. Depth grows with capacity, so check the door swing and the cable bend radius against your actual room, not against the footprint on a drawing.
Where it goes
Rack batteries are cheaper per kWh and better at scale. A cabinet wins where there is no room, no rack and nobody on site with a torque wrench.
01
Peak shaving behind the meter where the electrical room is already full. One cabinet, one wall circuit.
02
Store the midday surplus instead of exporting it at a negative price. Pairs with our own modules on the same site.
03
Where the outage is measured in hours, not seconds. 200 A discharge carries a real load, not just a router.
04
Delivered assembled. No on-site cell stacking, no busbar torquing, no specialist labour.
System thinking
A cabinet on its own is a component. What most projects actually need is a PV array, a storage unit and a controller that agree with each other — and a single party accountable when they do not.
Send 30 days of interval data and we will size the cabinet against your actual peak, not against a rule of thumb.
RS485/CAN with selectable protocols. Tell us the inverter model before you order — protocol matching after delivery is expensive.
When the array and the cabinet come from us, the warranty question has one answer instead of two.
Peak demand, daily cycle, backup hours required, inverter model. We will come back with a cabinet size and an honest note if storage is the wrong answer for your tariff.